Design and Development of Optimum Lighting Parameters for Haul Roads in Surface Coal Mines Using MATLAB Software Program - A Case Study

N.Lakshmipathy1, Ch.S.N.Murthy2, M. Aruna 3
  1. Asst. Professor, Dept. of Electrical & Electronics Engg., Dr.TTIT, Oorgaum, K.G.F – 563120, India
  2. Professor, Dept. of Mining Engg., NITK, Surathkal, Mangalore – 575025, India.
  3. Professor, Dept. of Mining Engg., NITK, Surathkal, Mangalore – 575025, India.
Related article at Pubmed, Scholar Google

Visit for more related articles at International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering

Abstract

In surface mines where natural light is not available especially during night hours artificial light is provided for better seeing, which facilitates increased production, reduce workers fatigue, protect their health, eyes and nervous system, and reduce accidents. One major problem in surface mine lighting is continuous changing of task place, including roadways. Because of this reason, it is difficult to provide any kind of long term permanent structure for illumination. Hence, the shifting of lighting installations at regular interval is very much necessary, so as to ensure required light level, as per the lighting standards specified by various regulatory bodies.

INTRODUCTION

In mines particularly haul road lighting is a critical concern for mines authorities. Because compared to other locations of mines illuminating haul roads is quite tedious and complex in nature. This is mainly because the haul roads are continuously moving, which requires regular shifting of light poles/lamps. Inefficient lighting wastes significant financial resources each year and also poor lighting creates unsafe conditions. Energy efficient technologies and proper design of lighting system can cut haul roads lighting costs dramatically often by 25-60 % (NYCGP 2009) and also it improves safety and comfort of miners. A well-designed, energy-efficient haul road lighting system should permit users to travel at night with good visibility, in safety and comfort, while reducing energy use and costs and enhancing the appearance of the neighborhood. Conversely, poorly designed lighting systems can lead to poor visibility or light pollution, or both. Quite often, haul roads lighting is poorly designed and inadequately maintained (e.g., there are large numbers of burned-out lamps), and uses obsolete lighting technology—thus consuming large amounts of energy and financial resources, while often failing to provide high-quality lighting (USAID June 2010). The Bureau of Energy Efficiency, based on Central Electricity Authority statistics, has estimated gross energy consumption for public lighting to be 6,131 million kWh in India for the years 2007-2008.
In order to provide a comfortable light level in the mines, as per the prevailing guidelines, a systematic illumination survey needs to be conducted. In this regard, as a case study, an illumination survey was conducted in a large mechanized surface coal mine of a country. As a In order to assess the status of illumination in surface coal mines, systematic illumination is needed to be conducted using appropriate statutory guidelines, so that effective control measures can be taken. Keeping this in view, illumination study in of the mechanized surface coal mine is considered for case study.
Then an attempt is made to design a program that gives a real time survey data of illumination in mines. The program is developed on the MATLAB platform. The program gives a real time lux data, 3-D charts, 3-D graph, 2-D plot and also source comparison table. The program also read out the height of the mounting also.

ENERGY-EFFICIENT LIGHTING

In the last few years, technological advancements in lighting have led to the development of energy-efficient lighting systems that consist of one or more components as listed below:
Low loss ballasts
Constant wattage, high intensity electronic ballasts
Energy-efficient luminaries
Better monitoring and control mechanisms
Guidance for lighting of public streets, roads, haul roads and highways is provided in the Bureau of Indian Standard (BIS, 1981). The most common reasons for inefficient haul road lighting systems in surface mines are:
Selection of inefficient luminaries
Poor design and installation
Poor power quality
Poor operation and maintenance practices
There is tremendous potential to improve lighting quality and operation and maintenance (O&M) practices while reducing energy consumption and greenhouse gas emissions-through energy-efficient retrofits (NYSERDA 2002). The efficiency of lighting system can also be significantly improved by selecting appropriate optics for the luminaries as well as ensuring proper design parameters, like mounting height, overhang, tilt angle etc. during installation of light sources.

A) Lamp Technology

The most important element of the illumination system is the light source. An electric light source is a device, which transforms electrical energy or power (in watts), into visible electromagnetic radiation or light (lumens). The rate of converting electrical energy into visible light is called “luminous efficacy” and is measured in lumens per watt (NYCGP 2009). It is the principal determinant of the visual quality, cost and energy efficiency aspects of the illumination system (NYCGP 2009).

B) Advantages of Energy-Efficient Lighting System

By adopting new and energy-efficient technologies and introducing procurement practices that promote the purchase of these technologies, large energy and cost savings can be achieved (NYCGP 2009). Considering the variable power quality conditions, selection of lamps that operate over a wide range of power parameters would significantly reduce the replacement costs of the lamps by reducing the failure rate, although it may entail a high initial investment cost. Further, good lighting can enhance visibility and safety, and helps to reduce consumption of electricity and reduction in costs, so as to free up resources for other pressing needs, thereby contributing to the improvement of the overall quality of life.

SYSTEM OF LIGHTING IN SURFACE MINES

One of the important aspects of designing lighting system is to determine the optimum position of the luminaries and the capacity of the light sources. Sources may be mounted on poles, towers and masts as per the convenience of mining operations. The modern heavy-duty face machinery dictate increasing in the bench height, forcing individual face lighting system, mounted on tripods. Individual lights may also be provided at active zones in addition to the general lighting scheme. In general, luminaries are mounted on:
Machines used in the mines
Movable telescopic as well as tiltable trolley mounted lighting mast
Low height (1.5- 2.0 m) tripods for spot face lighting
Towers erected on planned locations outside the blasting zone
Generally lamps mounted on tripods are used near the loading machines at the face. The cable wheel may be placed at one end, so that the cable can be stretched along the length of the face. Telescopic lighting mast (also called mobile lighting towers) either self-powered or towable type is used at the place, where more number of activities is carried out simultaneously. In some critical areas such as dumpyards, stackyards etc. where the dumping activities and vehicle movement are being carried out, it is advisable to go for movable lighting system connected to the main lighting scheme (Sigma Search Lights 2000).

A) Haul Road Illumination

Among all available lamp mounting systems, swage (insertion) type steel tubular poles are commonly used for haul road and other general lighting in surface mines. The specifications of light poles are given in Bureau of Indian Standard (BIS, 1981). In mines light poles are erected on single side of haul roads, i.e. along the length of crest of the face. In most of the Indian mines the height of the poles vary from 7 m to 12 m, with the angle of the light arm vary from 35º to 70º vertically upward with horizontal.

B) Methods for Calculating Illumination

The fig 3.1 gives to determine the Illuminance on a horizontal plane, to calculate the Illuminance first step is to determine how much flux is to be received.
image
where
MF = Maintenance factor (Light Loss Factor LLF)
UF = Utilization factor
The maintenance factor gives an estimate of how lighting conditions will deteriorate through use. Some factors are
· Dust and dirt inside luminaire surfaces.
· Aging of light bulbs emitting less light.
Cleaning of room surfaces, e.g. ceiling without detailed knowledge of a maintenance plan, one sets MF = 0.80. where,
‘S’ is the source.
‘P’ is the point at which illuminance is to be measured.
‘a’ is the width of the road.
‘b’ is the width of the road along C-plane.
‘γ' ‘is the angle between the vertical and the line joining inclined distance from the source to the point of measurement.
‘h’ is the height of the source from ground.
image

FORMULAE

AREA (A) =LENGTH * BREADTH.
IN CLINATION ANGLE(COS ф)=(x/r)
INTENSITY(I)=POWER/(4**AREA)
ANGLE GAMMA= COS(-1)(h/r)
ANGLE C=TAN (-1)(a/b)
HORIZONTAL ILLUMINATION=(I*COSф*UF)/(A2)*IMF
VERTICAL ILLUMINATION=(I*SIN У*UF)/(A2)*IMF
UNIFORMITY RATIO=(MAX ILLUMINATION/MIN ILLUMINATION).

C) MATLAB Aided Design of Lighting System

The computer programs employed for the calculation of the above illuminance, luminance can be structured various degrees of sophistication. MATLAB is a high-performance language for technical computing. It integrates computation, visualization, and programming in an easy-to-use environment where problems and solutions are expressed in familiar mathematical notation.
Typical features include:
Math and computation.
Algorithm development.
Modeling, simulation, and prototyping.
Data analysis, exploration, and visualization.
Scientific and engineering graphics.
Application development, including Graphical User Interface building.

D) Field Study

As a case study, an illumination survey was carried in a mechanized surface coal mine, where horizontal and vertical lux levels were measured using digital luxmeter. This table indicates the illuminance lux levels measured at each grid point using digital Luxmeter for parameters such as Power rating of the Source, height of the tower, Width of the road, Length of the measuring Field, Tilt angle Overhanging extension, etc as indicated under the test conditions

PRACTICAL OUTPUT

Table 4.1: High Pressure Sodium Vapour Lamp Fitted At the Center of the Field (in one of mechanized coal mine in A.P)
Source: High Pressure Sodium Vapour Lamp
Height of Tower: 6m
Width of the Road: 3m
Length of the measuring Field: 7m
Tilt angle: 12 degree
Overhanging extension: 2m
Power: 250w
H : Horizontal reading and V: Vertical reading
image
Source: High Pressure Sodium Vapour Lamp
Height of tower: 6m
Width of the road: 3m
Length of the measuring field: 7m
Tilt angle: 12 degree
Overhanging extension: 2m
power: 250w
image

A) Flowchart of the program

Figure 4.1 shows the flowchart for Illumination Design in MATLAB for an surface coal Mine Haul Road, taking the parameters, such as the types of sources (1:CFL 2: Florescent 3: Incandescent 4: Metal halides 5: High pressure sodium vapour ); it gives whether the source is fitted at the center of the field, total height of source from ground, total width of the road, total length of the measuring field, enter 1: overhanging 2: beyond kerb 3: above the kerb, enter the tilt angle in degree, enter the extension of source, etc. are the data’s governing for Horizontal reading and Vertical reading, Uniformity ratio, etc. the flow chart indicates if the Uniformity ratio is not equal to 0.3, it checks for the for loop for how much is the extra power needed to get Uniformity ratio to be equal to 0.3.
image

MATLAB OUTPUT

A) Design parameters of a single High pressure sodium Vapour lamp fitted at the center of the field
Illumination of road lighting of open cast mines
Enter the number source 1: Single source 2: Double source = 1
Illumination of road lighting with single source
Enter the type of sources 1: CFL 2: Fluorescent 3: Incandescent 4: Metal halides 5: High pressure Sodium Vapour: = 5
High pressure Sodium Vapour lamp Source fitted at the center of the field
Total height of Source from ground in m=6
Total width of the Road in m=3
Total length of the measuring field in m=7
Enter 1: Overhanging 2: beyond Kerb 3: above the Kerb 1
Enter the tilt angle in degree =12
Enter the extension of source in m=2
Enter 1: Lux data for vertical illumination
Distance along the z-plane A =1
Distance along the x-plane B =1
A: B Ratio = 1
Utilization Factor (UF) = 0.8000
Inverse Maintenance Factor (IMF) =1.2000

Program output

image
After comparing from Table 4.1 of practical output with Table 5.1 of MATLAB output for Horizontal Illumination Field along the Road with Source at the Centre % Error was found to be = ± 2-5
After comparing from Table 4.1 of practical output with Table 5.2 of MATLAB output for Vertical Illumination Field along the Road with Source at the Centre % Error was found to be = ± 2-5 %
image
image
image
Table 5.3, 5.4 shows the C – Values and Gamma values for illumination field along the Road with Source at the centre
Max_Illumination =1.3365,
Min_Illumination = 0.1153
Uniformity Ratio = 0.0863
To get a Uniformity ratio of = 0.3
Required Power = 150.2763
Enter 1: Horizontal 3D = 1
Enter 2: Vertical 3D = 2
Enter 3: plot = 3
image
Construction of tower and source calculation led as per standardize value and requirement enter the standard illumination required in lux = 10. The Fig.5.1 shows the Horizontal illumination at variable distance with source at the center for a 100w Compact Fluorescent Lamp (CFL) mounted at a height of 6.0m with the tilt angle 12 degrees. The Fig.5.2 shows the Vertical illumination at variable distance with source at the center for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees. The Fig.5.3 shows the 3-D plot for horizontal illumination at variable distance with source at the center for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees. The Fig.5.4 shows the 3-D plot for vertical illumination at variable distance with single source at the center for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees.
image
image
image
image
image
The Graph.5.1 shows the 2-D plot for horizontal and vertical illumination at variable distance with source at the center for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees.
From the literature survey the Table 5.5: shows the parameters such as source wattage, its operating voltage, current rating, output lumens, efficacy, source life and its approximate cost in the source comparison table for 1) CFL 2) Fluorescent 3) Incandescent 4) Metal halides 5) high pressure sodium vapour.

B) Design parameters of a High pressure sodium vapour lamp fitted at both end of the field

Illumination of road lighting of open cast mines
Enter the number source = 1: Single Source 2: Double Source =2
Illumination of Road Lighting with Double Source
Enter 1: CFL 2: Fluorescent 3: Incandescent 4: Metal halides 5: High Pressure Sodium Vapour: = 5
High pressure Sodium Vapour Lamp
Two Sources fitted at the Field
Total height of Source from ground in m =6
Total width of the road in m =3
Total length of the Measuring Field in m = 7
Enter 1: Overhanging 2: Beyond Kerb 3: Above Kerb 1
Enter the tilt angle in degree =12
Enter the extension of source in m =2
Enter 1: Lux data for vertical Illumination: 1
Distance along the z-plane A =1
Distance along the x-plane B =1
A: B ratio, Ratio =1
Utilization factor
UF = 0.8000
Inverse Maintanance factor
IMF =1.2000
Table 5.6 shows Horizontal Illumination field along the road with two sources
image
After comparing from Table 4.2 of practical output with Table 5.6 of MATLAB output for Horizontal Illumination Field along the Road with two Source at the Centre % Error was found to be = ± 2-5
image
After comparing from Table 4.2 of practical output with Table 5.7 of MATLAB output for Vertical Illumination Field along the Road with two Source at the Centre % Error was found to be = ± 2-5
image
Table 5.3, 5.4 shows the C – Values and Gamma values for illumination field along the Road with two Sources at the centre
image
UNIFORMITYRATIO
Max_Illumination =1.4088,
Min_Illumination = 0.2659
Uniformity Ratio =0.1887
To get a Uniformity Ratio of =0.3
Required Power =158.4040
Enter 1: Horizontal 3D = 1
Enter 2: Vertical 3D = 2
Enter 3: Plot = 3

C) Construction of Tower and Source Calculation as Per Standardize Value and Requirement

Enter the standard Illumination required in lux = 20
Enter the Wattage of light in watt =150
Enter the standard angle required in Degree = 10
Enter the Width of the Road in m =3
Mounted_height = 4.6673
image
image
The Fig.5.5 shows the Horizontal illumination at variable distance with two sources for a100w Compact Fluorescent Lamp (CFL) mounted at a height of 6.0m with the tilt angle 12 degrees. The Fig.5.6 shows the vertical illumination at variable distance with two sources for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees. The Fig.5.7 shows the3-D plot for horizontal illumination at variable distance with two sources for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees. tilt angle 12 degrees. The Fig.5.8 shows the 3-D plot for vertical illumination at variable distance with two sources at the center for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees Graph.5.2 shows the 2-D plot for horizontal and vertical illumination at variable distance with two sources for a100w CFL mounted at a height of 6.0m with the tilt angle 12 degrees.
image
Fig-5.7: 3-D plot for horizontal illumination at variable distance with two sources
image
Fig-5.8: 3-D plot for vertical illumination at variable distance with two sources
image
Graph-5.2: 2-D plot for horizontal and vertical illumination

ANALYSIS

It has to be borne in mind that optimum design achieved is valid only for the chosen illumination standards. In fact the design parameters i.e. spacing and number of poles will vary with the change in standards. In overall the experimental study reveals that height of mounting with tilt angle is very important to achieve all the required lighting standards at the same time.
In general, for surface coal mine lighting luminaries are fitted giving some tilt angle. This restricts the direct application of fundamental lighting law namely, the cosine law. Since the illuminating surface is not perpendicular to the axis of luminaire. The mathematical model has been developed keeping this aspect in view. The computer program developed on MATLAB takes care of the tilt effect for each and every grid point of illuminating surface. The program computes the light level at any given point taking into consideration of the cumulative effect of the light sources.

CONCLUSION

Minimum height of lighting installation, in general, should be governed by HEMM of maximum height moving on the road. Pole height may be varied from 12 to 16 meters for haul roads of around 12 meters width, which is usually prevailing in Indian surface coal mines.
Lamp selection is made mainly based on efficacy and suitability to each situation. Because of long life and efficient penetration character in dusty and foggy environment high pressure sodium vapor lamps are giving very good performance in surface coal mine lighting. For small projects lighting can be designed based on optimum energy consumption. No doubt, energy efficient design has a tremendous impact on cost. But the final decision on which lighting system is to be installed should be based on total cost, which should include the initial cost of the installation as well as its operating and maintenance cost.

References

  1. 1) Anon., Effective Mine Lighting Increases Safety, Production, Canadian Mining Journal, July, 1984, pp. 29-30.
  2. Anon., Report of The Mine Lighting Sub Committee to the National illumination Committee of Great Britain, Transactions of The Institution of the Mining Engineers, vol. 114, 1954-55, pp.189-220.
  3. Arthur, H. Bull, Mine Lighting by Portable Units, Journals of Mines, Metals and Fuels, 1962, 460-466.
  4. Aruna, M. , and Rao, Y. V. , Design of Cost Effective Illumination System for Surface Mine haul roads - A Case Study, Journal of the Institution of Engineers( India ), Feb 2010, 10-15.
  5. Aruna, M. , Rao, Y. V. ,Harsha Vardhan and Karmakar N.C., Some Problems in Mine Lighting, ISLE Light Newsletter, IV, 2004, 34-38.
  6. Aruna, M.,Rao, Y. V. and Karmakar, N.C., Design of Illumination System in Opencast Mines, Proceedings of 19th World Mining Congress, 2003, 1149-1157.
  7. Aruna, M., Evaluation of Illumination System in Opencast Mine and Development of Optimum Design Parameters, Unpublished Ph.D Thesis, Indian School of Mines University, Dhanbad, November 2008,PP. 4 -11
  8. Bell, B.W., Lighting in coal Mines, Proceedings of the Symposium on Environmental Engineering in Coal Mining, London, November,1972, pp,63-71.
  9. Totter, A.D, The Lighting of Underground Mines, Trans Tech Publications, West Germany, First Edition, 1982.
  10. BIS (Bureau of Indian Standards) 1981. Indian Standard, code of practice for lightning of public thoroughfares, IS 1944-7: 1981 (R2003). New Delhi, India.
  11. BIS (Bureau of Indian standards), Indian Standard code of Practice for Lighting of Public thoroughfares, IS: 1944 (Part land II), 1970.
  12. Black, W. F.,The Effect of a Dirty Atmosphere on the Output of Lighting Fittings, Light ., 1956, 49, 362-365.
  13. Chironis, P. N., Underground Mine Lighting. A Look At What’s New In Concepts And Equipment, Coal Age, August, 1974, pp. 66-74
  14. CIE (Commission Internationale de L’ Eclairage, Austria), Design Methods for Lighting of Roads, publication No. 132, 1999.
  15. CIE (Commission Internationale de L’ Eclairage, Austria), Street Lighting and Accidents, Publication No.8/2 (TC-4.6), 1979.
  16. CMR (Coal Mine Regulations), India, 1957.
  17. Einhorn, H. D., Dr. Ing., the IES code Glare Assement and Super-additivity, Trans. Illumination Eng. Soc.(London), Vol.27, No.3, 1962, 143-145.
  18. Einhorn,D.H.,Colour Science and Lighting Practice,Light and Lighting, vol.51, No.9,September,1958, pp.303-308.
  19. Ginhorn, D. H., "Colour Science and Lighting Practice", Light and Lighting, vol. 51, no. 9, September, 1958, pp. 303-308.
  20. Gupta, R.P., Dr. U. Prasad, Dr.P.K. Sadhu, Dr. N.Pal, Efficient Lighting system for Underground coal mines using LED, journal of the Institution of engineers (India), Vol.91, Aug.2010, 21-24
  21. IAEEL (international association for energy efficient lighting), 1995. Power quality and lighting [online]. IAEEL newsletter 3-4/95. Available from: www.iaeel.org/iaeel/newsl/1995/trefyra1995/litech_a_3_4_95.html
  22. New York City Global Partners (NYCGP) 2009. Best Practice: LED Street Lighting Energy and Efficiency Program. Los Angeles, USA.
  23. Sigma Search Lights, Manufactures Catalogue, 2000
  24. United States Agency International Development (USAID Version 2.0 — June, 2010), Energy-Efficient Street Lighting Guidelines.pdf.